What formula is used?
Useful heat is U-value × area × temperature difference × hours, converted from Wh to kWh.
Compare current and improved U-values using area, temperature difference, heating hours, system efficiency and energy price.
Useful heat reduction: 3060 kWh/year
Purchased energy reduction: 3400 kWh/year
Simple payback: 12.6 years
Uses Q = U × area × temperature difference × hours. This simplified steady-state estimate excludes ventilation, thermal bridges, solar/internal gains, rebound effects and installation-specific performance. Obtain a qualified assessment before building work.
Applies the steady-state U-value heat-flow equation to an annual scenario.
Input: 60 m², 12°C difference, 2,500 heating hours
Output: Useful heat and annual cost reduction
Useful heat is U-value × area × temperature difference × hours, converted from Wh to kWh.
No. It omits ventilation, thermal bridges, gains, moisture and installation-specific performance.
Use measured, documented or professionally assessed values suitable for the construction.